Skip to main content
£0.00 0

Basket

No products in the basket.

MINING BUNDLE

220x Antminer S21 319TH + ANTSPACE HD5 Container · T-type

SHA-256 · 70.18 PH/s

220 miners · Hydro cooling · With container

In stock
ANTSPACE HD5 1.5MW Mining Container — 1 included
Antminer S21 — 220 included

Catalogue preview — this bundle is not available to order yet.

Hashrate
70.18 PH/s319 TH/s each
Algorithm
SHA-256
Efficiency
16W/TH
Power
1.12MW5.1kW each
Miner Load
1.12MWAuxiliary power pending
Earns/kWh
Pending
Solo · QuaiAuto · Annual comparison
Equipment Price
£560,970.00Ex VAT£647,860.00

Total Saving £86,890.00

£829,202.99₿13.26106933 equivalentGross Payback

Component Miner Rankings

Component miner ranking #51
220x Bitmain Antminer S21 Hydro 319Th SHA-256 Bitcoin MinerOverall #51 · Earnings #155 · Efficiency #184 · Value #58 · ROI #76

These are the included individual miners’ existing ranks. Bundle economics use the complete configuration price, delivery, discount and auxiliary power. Mixed fleets show an average component percentage score, with the individual ranks in its breakdown.

Selected Equipment Schedule

220 miners · Pending operating load. Only the following quantities and products are included in this configuration.

EquipmentQuantityRole
Bitmain Antminer S21 Hydro 319Th SHA-256 Bitcoin Miner220Miner
Bitmain ANTSPACE HD5 1.5MW Hydro Mining Container1Infrastructure

Container Layout · T-type.

Container Planning & Headroom

Provisional maximum per container: 220 miners, in 2 equal groups. Quantities allow 5% above listed miner power and reserve 10% of reference cooling and electrical capacity, and of flow where published. This is a planning allowance, not installation approval.

Miner Design Load
1.18MW
Auxiliary Electrical Allowance
180kW
Cooling Headroom
220.98kW
Coolant Flow Allowance
132.00 m³/h

Auxiliary allowances are conservative design bounds, not average electricity consumption. Running costs remain unconfirmed until the complete load schedule is supplied.

Normal stock operation, no overclocking. Hydro inlet at or below 35 C. Site ambient, fluid, pressure, branch circuits and delivered revision require confirmation.

1512kW is a deliberately conservative planning ceiling, not a claim about gross electrical capacity. Budget the separate container/tower bounds of 100+80kW without claiming concurrent measured draw; possible overlap remains unresolved. Only the container 100kW bound is charged to the liquid circuit. 73.9m3/h per side; equal A/B allocation.

Individual Miner Connection

The miner maximum input current exceeds the published bay reference. Confirm a compatible delivered branch/PDU revision; reducing miner quantity does not resolve this.

Miner Maximum Input
12A
Published Bay Reference
10A

Miner electrical specification

Manufacturer Equipment Reference

Container with two distribution cabinets and two cooling circuits, matched 1500kW dry tower (750kW per side), controls and DN100 PN16 connections. The manual describes connecting pipework; the delivered packing list must establish its supply.

Outstanding Supplier Checks

  • Confirm the delivered manual revision and that the priced package includes the matched tower, pumps, connecting pipework and coolant.
  • Reconcile the 100kW container and 80kW tower limits before treating their sum as actual auxiliary consumption.
  • The S21 Hydro V4.0.14 guide specifies 12A maximum versus the 10A bay reference. Obtain a matching delivered branch/PDU revision and circuit/connector schedule; reducing fleet quantity does not resolve this. Confirm cooling duty, site supply and pump flow at operating pressure.

Manufacturer reference

Price Breakdown & Volume Discount
Miner Subtotal
£535,260.00
Infrastructure Subtotal
£68,100.00
Miner Discount
15%
Recorded AER Delivery Allowances
£44,500.00

The volume discount applies once to current published miner prices, including their embedded delivery allowance. Freight enters the complete package total once. Infrastructure is not discounted. Existing AER £10 rounding applies. Unconfirmed amounts are indicative, not an orderable offer.

Power Consumption & Installation Requirements

Miner Load
1.12MW
Auxiliaries
Unconfirmed
Known Load Only
1.12MW
Energy per 24 Hours
26,949.12kWh

Miner-only consumption is shown while auxiliary power is unconfirmed. Pumps, fans, controls and other site loads must be added; this is not a complete operating total.

Mining Earnings & Block Odds

Scenario, odds & assumptions

Constant-condition scenario, not a forecast. 100% operating time, £0.000/kWh, 2% pool service fee and 0% Solo service fee. Fees are editable assumptions; confirm your chosen provider’s charges. Network transaction rewards are included in the shared source estimate.

Operating power Pending includes Pending auxiliaries. Miner quantities are fixed. Auxiliary inputs must cover the listed cooling equipment.

Bitcoin equivalent is a display conversion of the selected mining routes, not a claim that the hardware mines Bitcoin. Recorded Bitcoin price £62,529.12 at 2026-10-21T11:03:09+00:00.

Auto selects the highest expected annual return after the entered fees and operating electricity for each algorithm. Equipment cost is fixed for the selected configuration. A higher expected Solo return does not mean a reliable payout.

Quai Expected Blocks / Year
14,281,677.996632
At Least One Block
≈100%
No Blocks
<0.0001%
Block Value
£0.06

Block probabilities use this fleet’s actual hashrate over the selected timeframe. Fractional expected blocks are a statistical average, not part of a block paid to you.

Excludes hosting, maintenance, taxes, finance and other operating charges not explicitly entered. Prices, difficulty, rewards and uptime can change. Network inputs: . Calculated .

Annual alternatives after mining fees, before shared electricity costs
Asset / ModeExpected Earnings
SHA-256 · Quai · Solo£829,202.99
SHA-256 · eCash · Solo£802,456.91
SHA-256 · Fractal Bitcoin · Solo£742,074.73
SHA-256 · Bitcoin Cash · Solo£741,685.16
SHA-256 · Bitcoin Cash · Pool£732,697.37
SHA-256 · Bitcoin · Solo£723,296.42
SHA-256 · eCash · Pool£719,991.63
SHA-256 · Fractal Bitcoin · Pool£694,423.30
SHA-256 · Bitcoin · Pool£692,540.97
SHA-256 · Bitcoin · Pool£691,286.08
SHA-256 · Quai · Pool£678,580.35
SHA-256 · DigiByte · Pool£522,346.87
SHA-256 · DigiByte · Solo£499,646.83

Equipment Scope & Site Requirements

The selected equipment schedule itemises the miners and container(s). Manufacturer system reference: Container with two distribution cabinets and two cooling circuits, matched 1500kW dry tower (750kW per side), controls and DN100 PN16 connections. The manual describes connecting pipework; the delivered packing list must establish its supply. The saved price record does not independently confirm the supplied packing list. Final tower, pump, controls, pipework, miner connections and coolant inclusions require supplier confirmation.

Site works, upstream electrical supply, networking, commissioning, maintenance and any equipment not itemised.

Availability

This configuration is a draft and is not available to buy yet. The included equipment, pricing and stock must be complete before it is listed for sale.

Outstanding Configuration Checks
  • State auxiliary power and reserve explicitly.
  • Complete-package delivery allowance is missing.
  • Infrastructure capacities need verification.
  • Auxiliary load must include the infrastructure auxiliaries.
  • Itemise the complete auxiliary load, including pumps, fans, coolers and controls.
  • The complete auxiliary schedule must match the reviewed per-module loads; external loads cannot bypass module capacity checks.
  • Electrical supply capacity is missing.
  • Record the installation electrical reserve explicitly.
  • Exact equipment fit and installation design need confirmation.
  • Record the reviewed electrical design and its evidence.
  • Record the reviewed cooling design and its evidence.
  • Record the reviewed ancillaries design and its evidence.
  • The miner maximum input current exceeds the published bay reference. Confirm a compatible delivered branch/PDU revision; reducing miner quantity does not resolve this.
  • No valid per-module placement was found for the fleet and cooling limits.
  • Planning headroom is provisional; confirm the supplied revision, site conditions and complete auxiliary schedule before installation approval.
  • The component specification or price changed; review this package.