MINING BUNDLE
320x Antminer S19k Pro 120TH + 2x ANTSPACE MD5 Container · Air Models for Immersion
SHA-256 · 38.4 PH/s
320 miners · Immersion cooling · With container
Pre-Order


Catalogue preview — this bundle is not available to order yet.
- Hashrate
- 38.4 PH/s120 TH/s each
- Algorithm
- SHA-256
- Efficiency
- 23W/TH
- Power
- 883.2kW2.76kW each
- Miner Load
- 883.2kWAuxiliary power pending
- Earns/kWh
- Pending
Total Saving £166,400.00
Component Miner Rankings
These are the included individual miners’ existing ranks. Bundle economics use the complete configuration price, delivery, discount and auxiliary power. Mixed fleets show an average component percentage score, with the individual ranks in its breakdown.
Selected Equipment Schedule
320 miners · Pending operating load. Only the following quantities and products are included in this configuration.
| Equipment | Quantity | Role |
|---|---|---|
| Bitmain Antminer S19k Pro 120Th SHA-256 Bitcoin Miner | 320 | Miner |
| Bitmain ANTSPACE MD5 1MW Immersion Mining Container | 2 | Infrastructure |
Container Layout · Air Models for Immersion. Air-model immersion conversion proposal. Confirm model dimensions, fluid compatibility, PSU, fan/firmware preparation, electrical connections and preparation costs. Stock power and hashrate are unchanged. The 160 positions are the container reference, not confirmed capacity for these converted models.
Antminer S19k Pro · Air Model for Immersion — Use the original air-cooled miner prepared for immersion. Confirm compatible fluid, PSU and electrical connections, fan/firmware preparation and itemised preparation costs. Catalogue hashrate and power are retained without assumed overclocking or savings.
Price Breakdown & Volume Discount
- Miner Subtotal
- £192,000.00
- Infrastructure Subtotal
- £198,200.00
- Miner Discount
- 15%
- Recorded AER Delivery Allowances
- £65,000.00
The volume discount applies once to current published miner prices, including their embedded delivery allowance. Freight enters the complete package total once. Infrastructure is not discounted. Existing AER £10 rounding applies. Unconfirmed amounts are indicative, not an orderable offer.
Power Consumption & Installation Requirements
- Miner Load
- 883.2kW
- Auxiliaries
- Unconfirmed
- Known Load Only
- 883.2kW
- Energy per 24 Hours
- 21,196.8kWh
Miner-only consumption is shown while auxiliary power is unconfirmed. Pumps, fans, controls and other site loads must be added; this is not a complete operating total.
Mining Earnings & Block Odds
Scenario, odds & assumptions
Constant-condition scenario, not a forecast. 100% operating time, £0.000/kWh, 2% pool service fee and 0% Solo service fee. Fees are editable assumptions; confirm your chosen provider’s charges. Network transaction rewards are included in the shared source estimate.
Operating power Pending includes Pending auxiliaries. Miner quantities are fixed. Auxiliary inputs must cover the listed cooling equipment.
Bitcoin equivalent is a display conversion of the selected mining routes, not a claim that the hardware mines Bitcoin. Recorded Bitcoin price £62,490.16 at 2026-10-21T10:13:07+00:00.
Auto selects the highest expected annual return after the entered fees and operating electricity for each algorithm. Equipment cost is fixed for the selected configuration. A higher expected Solo return does not mean a reliable payout.
- eCash Expected Blocks / Year
- 48,503.252456
- At Least One Block
- ≈100%
- No Blocks
- <0.0001%
- Block Value
- £9.06
Block probabilities use this fleet’s actual hashrate over the selected timeframe. Fractional expected blocks are a statistical average, not part of a block paid to you.
Excludes hosting, maintenance, taxes, finance and other operating charges not explicitly entered. Prices, difficulty, rewards and uptime can change. Network inputs: . Calculated .
| Asset / Mode | Expected Earnings |
|---|---|
| SHA-256 · eCash · Solo | £439,384.90 |
| SHA-256 · Quai · Solo | £420,461.20 |
| SHA-256 · Fractal Bitcoin · Solo | £410,576.35 |
| SHA-256 · Bitcoin Cash · Pool | £398,502.77 |
| SHA-256 · Bitcoin Cash · Solo | £396,567.23 |
| SHA-256 · eCash · Pool | £394,642.97 |
| SHA-256 · Bitcoin · Solo | £393,102.51 |
| SHA-256 · Fractal Bitcoin · Pool | £384,607.49 |
| SHA-256 · Bitcoin · Pool | £378,689.14 |
| SHA-256 · Bitcoin · Pool | £377,917.18 |
| SHA-256 · Quai · Pool | £369,597.17 |
| SHA-256 · DigiByte · Solo | £329,709.87 |
| SHA-256 · DigiByte · Pool | £282,194.17 |
Equipment Scope & Site Requirements
Only the quantities and equipment in this product’s schedule.
Site works, upstream electrical supply, networking, commissioning, maintenance and any equipment not itemised.
- Miners and exact supply batch — see the itemised schedule.
- Rack, tank or container and chassis compatibility — included only if expressly itemised; otherwise excluded.
- Pumps and coolant distribution — included only if expressly itemised; otherwise excluded.
- Dry cooler or heat exchanger — included only if expressly itemised; otherwise excluded.
- Immersion fluid or approved hydro coolant — included only if expressly itemised; otherwise excluded.
- Pipework, valves and connections — included only if expressly itemised; otherwise excluded.
- Electrical distribution, protection and cabling — included only if expressly itemised; otherwise excluded.
- Networking, commissioning and site work — included only if expressly itemised; otherwise excluded.
Availability
This configuration is a draft and is not available to buy yet. The included equipment, pricing and stock must be complete before it is listed for sale.
Outstanding Configuration Checks
- State auxiliary power and reserve explicitly.
- Air-model immersion preparation and its included costs need confirmation.
- Complete-package delivery allowance is missing.
- Infrastructure capacities need verification.
- Auxiliary load must include the infrastructure auxiliaries.
- Itemise the complete auxiliary load, including pumps, fans, coolers and controls.
- The complete auxiliary schedule must match the reviewed per-module loads; external loads cannot bypass module capacity checks.
- Electrical supply capacity is missing.
- Record the installation electrical reserve explicitly.
- Exact equipment fit and installation design need confirmation.
- Record the reviewed electrical design and its evidence.
- Record the reviewed cooling design and its evidence.
- Record the reviewed ancillaries design and its evidence.
- No valid per-module placement was found for the fleet and cooling limits.
- The component specification or price changed; review this package.